New
DC13500 front
Truck/Mining

DC13500

This rooftop air conditioner is designed for heavy-duty applications in operator cabs and electrical cabinets of mining vehicles. The robust housing is manufactured from powder-coated, zinc-plated steel and aluminum, finished in RAL 7035. The integrated controller displays all settings and fault codes. The compressor and refrigerant copper piping are additionally secured to the housing for increased durability.

Configuration:

Monoblock

Type:

Air to Air

Serie:

DC13000

Cooling Capacity:

0,54 kW

Heating Capacity:

-

Heating Options:

Cooling Only

Primary Voltage:

24/400/800 Vdc

Secondairy Voltage:

24 Vdc

Attachements:

Under development, files will be available soon.

Technical Overview

ParameterValue
Cooling capacity¹3,9 kW
COP¹2,7
Max airflow (indoor)800 m³/h
Voltage range 24 Vdc19–32 Vdc
Voltage range 48 Vdc²36–60 Vdc
Voltage range 400 Vdc²xx–xx Vdc
Voltage range 800 Vdc²xx–xx Vdc
Secondary voltage³24 Vdc
Secondary voltage range³19–32 Vdc
Control system CAN 2.0A/ B, J1939, CANopen, remote on/ off or selfcontrolled
Max ambient operating temperature⁴55 °C
Noise (outdoor/indoor)63/58 dB(A)
Size unit1083 x 757 x 262 mm (L x W x H)
Weight unit68 kg
RefrigerantR134a non-flammable A1 refrigerant- allowed to be used in EU for mobile applications for cooling batteries and equipment. 1234yf on request.
ColourRAL 7035
MaterialZinc-plated steel

¹ Tested in 30 °C 50% RH indoor / 35 °C outdoor at 26 Vdc. Cooling duty varies on climatic conditions and altitude, consult DC Airco for specific applications.
² Alternative voltages, consult DC Airco for specific details.
³ Secondary voltage of 24 Vdc is required for at least 5 minutes to provide afterrun time to cool down the electric heaters.
⁴ Simulating peak ambient temperature conditions during the day.

Made from 1,5 mm zinc-plated steel with a tough RAL 7035 powder coating, the housing resists corrosion and wear in harsh environments. An optional advanced controller can be added alongside the built-in PLC to enable remote system management and online monitoring. Alternative voltage configurations may be available, along with mechanical and electrical customizations depending on your application and order volume. Contact us to explore tailored solutions that meet your operational needs.

DC13500 Configurator

Chosen Product Code

DC13500[XXXX][XXX]
CategorieOptieProduct Code Letter (X)
FunctionCooling only0
Cooling + heating elements1
CommunicationCAN 2.0AA
CAN 2.0BB
CANopenC
J1939D
Hard wiredE
Standalone HMIF
Advance HMIG
Baud rate or set point value125 [kbit/s]A
250 [kbit/s]B
500 [kbit/s]C
1000 [kbit/s]D
20 [°C]E
25 [°C]F
30 [°C]G
Node ID with CAN communicationNot applicable (hard wired)A
CAN 2.0 A/B TX*(0x110, 0x111, 0x112) RX*(0x210)B
CAN 2.0 A/B TX*(0x790, 0x791, 0x792) RX*(0x793)C
CANopen Node ID 1D
CANopen Node ID 2E
J1939 TX*(0x0fffe02, 0x0ffff03, 0x0ffffc04) RX*(0x0fffd01)F
OthersNo othersA
Main voltage630 VDC [400 - 850 ± 5 VDC][630]
350 VDC [210 - 480 ± 5 VDC][350]
48 VDC [36 - 69 VDC][48]
24 VDC [19 - 32 VDC][24]
Control voltage48 VDC [36 - 69 VDC][48]
24 VDC [19 - 32 VDC][24]

Quotation Form

Not found?

Did you not find what you were looking for, contact us for custom possibilities.

Custom Products