| Parameter | Value |
|---|---|
| Cooling capacity¹ | 3,9 kW |
| COP¹ | 2,7 |
| Max airflow (indoor) | 800 m³/h |
| Voltage range 24 Vdc | 19–32 Vdc |
| Voltage range 48 Vdc² | 36–60 Vdc |
| Voltage range 400 Vdc² | xx–xx Vdc |
| Voltage range 800 Vdc² | xx–xx Vdc |
| Secondary voltage³ | 24 Vdc |
| Secondary voltage range³ | 19–32 Vdc |
| Control system | CAN 2.0A/ B, J1939, CANopen, remote on/ off or selfcontrolled |
| Max ambient operating temperature⁴ | 55 °C |
| Noise (outdoor/indoor) | 63/58 dB(A) |
| Size unit | 1083 x 757 x 262 mm (L x W x H) |
| Weight unit | 68 kg |
| Refrigerant | R134a non-flammable A1 refrigerant- allowed to be used in EU for mobile applications for cooling batteries and equipment. 1234yf on request. |
| Colour | RAL 7035 |
| Material | Zinc-plated steel |
¹ Tested in 30 °C 50% RH indoor / 35 °C outdoor at 26 Vdc. Cooling duty varies on climatic conditions and altitude, consult DC Airco for specific applications.
² Alternative voltages, consult DC Airco for specific details.
³ Secondary voltage of 24 Vdc is required for at least 5 minutes to provide afterrun time to cool down the electric heaters.
⁴ Simulating peak ambient temperature conditions during the day.
Made from 1,5 mm zinc-plated steel with a tough RAL 7035 powder coating, the housing resists corrosion and wear in harsh environments. An optional advanced controller can be added alongside the built-in PLC to enable remote system management and online monitoring. Alternative voltage configurations may be available, along with mechanical and electrical customizations depending on your application and order volume. Contact us to explore tailored solutions that meet your operational needs.