New
DC6030
Battery/Equipment, E-Mobility

DC6030

Redefining Battery Thermal Management System. Our compact reversible heat pump, designed for precision battery thermal management, ensures optimal temperatures for extended lifespan and utilises a cutting-edge liquid-liquid system. It ingeniously transforms your battery's heat into a valuable resource.

Configuration:

Split

Type:

Air to Liquid

Serie:

DC6000

Cooling Capacity:

38,5 kW

Heating Capacity:

-

Heating Options:

Cooling Only

Primary Voltage:

350/630 Vdc

Secondairy Voltage:

12/24 Vdc

Attachements:

Under development, files will be available soon.

Technical Overview

ParameterValue
Cooling capacity¹6,9 kW
COP cooling¹2,6
Power consumption0–3,4 kW
Voltage range 350 VDC model210–480 Vdc
Voltage range 630 VDC model400–850 Vdc
Control voltage9–40 Vdc
Control systemCAN 2.0A/ B, J1939, CANopen, remote on/ off or self-controlled
Flow side A18–30 l/min
Liquid connectionsG¾” male
Size251 x 346 x 344 mm (L x W x H) without condensor
RefrigerantR134a non-flammable A1 refrigerant- allowed to be used in EU for mobile applications for cooling batteries and equipment. 1234yf on request.
Weight19 kg (body without condensor)
ColourBare aluminium
MaterialAluminium

¹ Liquid A in 30 °C 20 l/min, outside ambient temperature 35 °C.

DC6030 Configurator

Chosen Product Code

DC6030[XXXX][XXX]
CategorieOptieProduct Code Letter (X)
CommunicationCAN 2.0AA
CAN 2.0BB
CANopenC
J1939D
Hard wiredE
Baud rate or set point value125 [kbit/s]A
250 [kbit/s]B
500 [kbit/s]C
1000 [kbit/s]D
20 [°C]E
25 [°C]F
30 [°C]G
Node ID with CAN communicationNot applicable (hard wired)A
CAN 2.0 A/B TX*(0x110, 0x111, 0x112) RX*(0x210)B
CAN 2.0 A/B TX*(0x790, 0x791, 0x792) RX*(0x793)C
CANopen Node ID 1D
CANopen Node ID 2E
J1939 TX*(0x0fffe02, 0x0ffff03, 0x0ffffc04) RX*(0x0fffd01)F
OthersNo othersA
HNBR O-ring seals A side (for immersion liquid)B
HV voltage630 VDC [400 - 850 ± 5 VDC][630]
350 VDC [210 - 480 ± 5 VDC][350]